Regolith Water LoopWater pre-treatment

Operating on Mars

What the environment forces on the design, the system sized for a crew of six, and the habitat requirements it has to meet.

Conditions and what they decide

ConditionValueDesign consequence
Liquid waterNot stable at surface pressure and temperatureEvery wet stage runs inside the pressurised habitat
Gravity3.7 m/s², 0.37 gFlow through a bed scales with g at a fixed head: 2.65× the filter area, or a taller head
TemperatureAbout 20 °C down to −153 °CHeated, insulated bioreactor; the reference strain is grown at 37 °C
Perchlorate0.4–0.6 % at Phoenix; 0.5–1 % in soils generally; also at Gale CraterRaw regolith is never filter medium; it passes Stage 1 first
RegolithBasalticBasaltic volcanic scoria as the bench analogue
Dust0.1 mg/m³, 24-hour average, below 10 µmRegolith handling sealed from cabin air and the water path
Water sourceShallow ground iceThe habitat mines ice; this system treats water after use
Planetary protectionCOSPAR policyStage 1 is closed; nothing living is vented or discharged

Sources for every row are on the references page.

Sized for six crew

Reproducible with rwl:

pipx install rwl
rwl size --crew 6 --base early --explain

Or move the crew and base live in the sizing simulator.

QuantityEarly baseMature base
Hygiene greywater33.2 L/day61.0 L/day
Continuous flow1.38 L/h2.54 L/h
Filter area, Earth g0.0035–0.014 m²0.0064–0.025 m²
Filter area, Mars g0.009–0.037 m²0.017–0.067 m²
Bench-size columns, Mars g2–84–15
Bed volume, Mars g4–15 L7–28 L
Trash8.3 kg/day8.3 kg/day
Char, dry basis0.82 kg/day0.82 kg/day
Retort heat5.0–7.6 MJ/day5.0–7.6 MJ/day

Greywater and trash rates come from NASA's Life Support Baseline Values document; filter rates are those of slow sand filtration, 0.1–0.4 m/h; char assumes food and paper are 47.5 % of trash and slow pyrolysis leaves 25 % of its dry mass as char.

The filter is small. A six-person base needs two to eight columns the size of the bench build, in parallel. That argues for modules: identical sealed cartridges swapped when spent, instead of one large bed dug out by hand.

Gravity: area or head

Flow through a packed bed follows Darcy's law, and the bed's hydraulic conductivity is proportional to g. At 0.37 g the same column passes 37.7 % of its Earth flow. There are two ways back:

EarthMars, same flow
More area, same head1 column2.65 columns
Same area, more head0.20 m of water over the bed1.22 m of water over the bed

With a free-draining outlet the driving gradient is (standing water + bed) ÷ bed, so the whole of it has to grow 2.65×, not just the water on top. A 1.2 m water column per cartridge is impractical inside a habitat; parallel cartridges are not. That is why the design adds area. The bench column's own conductivity, and the same bed at 0.37 g, come out of a timed run with rwl permeability.

Retort heat

Six crew, per dayAmountBasis
Feed, food and paper3.96 kg47.5 % of 8.34 kg trash
Moisture in the feed0.69 kgPlate waste 70 %, paper 10.2 %, unopened food 0.2 %
Pyrolysing the dry feed2.6–5.2 MJ0.8–1.6 MJ/kg near 500 °C
Water to steam at 500 °C2.3 MJ3.40 MJ/kg from 20 °C at 1 atm
Total5.0–7.6 MJ57–88 W averaged over a day

Moisture is from BVAD Table 4-28, pyrolysis energy from Daugaard and Brown, steam from NIST. The pyrolysis figures are for wood and crop residues in a fast reactor, not mixed food waste in a slow retort; they set the order of magnitude, not a design value, and wall losses are not included. Either way it is tens of watts on average, run as a batch.

Oxygen is a side product

Full reduction, with acetate as electron donor:

ClO₄⁻ + CH₃COO⁻ + H⁺ → Cl⁻ + 2 CO₂ + 2 H₂O

Per tonne of regolith0.4 % perchlorate1 % perchlorate
Perchlorate4.0 kg10.0 kg
Acetate, full reduction2.4 kg5.9 kg
O₂ if every molecule were captured1.3 kg3.2 kg

Why the design does not count on it

The bacteria respire that oxygen themselves. Six crew breathe 5.37 kg of O₂ a day; even perfect capture would take 1.7–4.2 tonnes of regolith treated daily. Stage 1 exists to detoxify.

Chloride

Every perchlorate reduced leaves one chloride ion behind: 1.43–3.56 kg per tonne of regolith. Diluting that to the 250 mg/L taste limit for chloride would take 5.7–14.3 m³ of water per tonne. Dilution is not an option on Mars, so the rinse is kept small and the brine goes to a brine processor of the kind already demonstrated on the ISS for urine brine.

What Mars supplies, what Earth supplies

One bench-size cartridge, taking the RWL-001 media schedule and counting every mineral layer as treated regolith:

rwl cartridge --crew 6
ItemAmountComes from
Treated regolith1.73 kgMars, Stage 1
Char0.16 kgMars, Stage 3; a day of trash makes enough for 5–6 cartridges
Acetate to detoxify the regolith4.1–10.3 gEarth, until a waste-derived donor works
Cartridge shell1Earth, refilled on site
Chloride left to rinse2.5–6.2 gBrine processor

The acetate is the stoichiometric minimum; bacteria also spend some donor on growth. For scale, the ISS water processor relies on expendable multifiltration beds that need about 472 kg of resupply a year. This design does not replace those beds and does not claim to extend their life by any measured amount. Its own media, by mass, is made on Mars.

The stages at mission scale

Stage 1, bioreactor. Closed, heated and anaerobic, treating regolith in batches with Azospira suillum PS and Dechloromonas aromatica RCB. The donor is supplied as acetate or lactate until a waste-derived donor is shown to work. Treated regolith is rinsed of chloride.

Stage 2, filter modules. Sealed cartridges with the RWL-001 layering, in parallel under gravity. Effluent goes to the main water processor, never straight to the crew.

Stage 3, pyrolysis. A closed retort for food and paper. Char goes to Stage 2, off-gas is scrubbed, and retort heat warms the Stage 1 jacket.

Flows are drawn in RWL-003 and placement in RWL-004, on the drawings page.

Habitat requirements

NASA-STD-3001 Volume 2, Revision E.

RequirementAsks forResponse
V2 6026 Potable Water QualitySafe potable water at the point of useNot claimed: this is pre-treatment, potability is the main processor's job
V2 6046 Water Quality MonitoringMonitor water and alert crewPhotographic turbidity as a low-cost trend check, not a certified sensor
V2 6051 Water Contamination ControlKeep water free of contamination, including dustRegolith handling and water path physically separate
V2 6052 Particulate MatterTotal dust < 3 mg/m³, respirable < 1 mg/m³Closed regolith transfer; cartridges never opened in the cabin
V2 6153 Celestial Dust MonitoringMonitor Martian dust and alert crewDust monitor at the handling glovebox
V2 6053 Lunar Dust ContaminationLunar dust < 0.3 mg/m³Lunar only; the stricter 0.1 mg/m³ Martian limit is used
V2 6050 Atmosphere Contamination LimitGases below maximum allowable concentrationsRetort off-gas scrubbed and sent to life support
V2 6004 Carbon Dioxide LevelsppCO₂ ≤ 3 mmHg, one-hour averageBioreactor and retort CO₂ ducted to life support

Open questions

  • Whether the retort's rejected heat covers the Stage 1 jacket, which depends on a reactor not yet designed
  • Whether the pyrolysis liquid can serve as electron donor
  • The rinse volume that gets chloride out of the regolith pores, which is not measured
  • Filtration with real Martian fines at 0.37 g, which is modelled, not measured