Regolith Water LoopWater pre-treatment

Materials

Everything here was chosen to be buyable in an ordinary Mexican hardware store, aquarium shop or garden centre. No laboratory equipment is required.

Column

ItemQuantityWhere
PVC pipe, 3 in750 mmhardware store
Volcanic scoria (lava rock), raw3 kggarden centre
Fine silica sand, aquarium grade~1.3 kgaquarium or pet shop
Lump charcoal, not briquettes~0.65 L crushedany grocery store
PVC end cap, 3 in1hardware store
Transparent hose, ½ in1 mhardware store
Plastic stopcock, ½ in1hardware store
Plastic insect mesh30 × 30 cmhardware store
Two-part epoxy1hardware store

The pipe is opaque, so the layers cannot be seen once loaded. Each one is photographed from above as it goes in, which records the build just as well. The silica sand is inert and leaves water chemistry unchanged. Hot-melt glue does not hold on wet PVC; seal the outlet with two-part epoxy.

Measurement

ItemQuantityNote
Identical glass jars6straight-sided, clear, no embossing
Syringes, no needle3 × 20 mlfor the dilution series
Kitchen measuring jug1 Lreplaces a graduated cylinder
Blue food colouring1strong, not pale
Neutral liquid soap1surfactant load
White card80 × 80 mmexposure reference
Printed checker target100 × 100 mmcontrast target
Constant lamp1any fixed light source

The checker target and the white card print together, at true size, on one A4 sheet.

Download target sheet (PDF)

Why the jars must be identical

Every sample is photographed through glass. Different thickness or curvature changes what the camera sees, and the series stops comparing anything. Six matching jam jars work as well as six bought ones.

Blue is not an arbitrary choice. Methylene blue uptake is a useful indicator of the adsorption capacity of activated carbon, so a blue tracer mirrors a real assay — and blue reads as dark grey once the photograph is converted, which is what the contrast measurement needs. Yellow reads almost white and is nearly invisible to the method.

Deliberately not required

Not neededInstead
Laboratory sieve stackInsect mesh as a single cut, aperture measured and reported
Precision balanceMedia placed by depth; volumes recorded rather than masses
GeotextileDiscs cut from the same insect mesh
Graduated cylinderKitchen measuring jug
Clamps and standColumn taped to a mop handle leaning on a wall
NephelometerPhotographs and the analysis code

Not handled

No perchlorates

Perchlorate salts are strong oxidisers. They are not used, not bought, and not required. Stage 1 is supported by published work; what the bench demonstrates is filtration and adsorption, measured with synthetic greywater mixed to a written recipe.